Filter Results By:

Products

Applications

Manufacturers

Showing results: 121 - 132 of 132 items found.

  • Battery Voltage Supervisor

    BVS - IBEKO Power AB

    DV Power battery voltage supervisor – BVS, is an accurate battery voltage monitoring system that monitors the state of health of battery systems. It records important battery parameters such as battery voltage, inter-cell connection voltage, and ambient temperature. Because of that, it can be a support tool for capacity testing.The BVS voltage supervisor is an integrated system consisting of:BVS Control Unit (BVS-CU)Cell Voltage Modules (CVM)String Voltage Module (SVM) (optional)String Current Module (SCM) (optional)It is an ideal testing tool for maintenance, troubleshooting and performance tests on individual stationary batteries and battery packs in critical backup energy solutions.BVS-CU provides ambient temperature measurements on multiple locations (4 temperature channels). Overall string voltage and string current monitoring can be achieved by using an optional string voltage module (SVM) and string current module (SCM).There are two types of DV Power battery voltage supervisors:BVS – One cell voltage module measures 1 cellBVS-4 – One cell voltage module measures 4 cellsCVM modules detect cells that fail a discharge test based on monitored voltage values. As a result of that, these cells can be safely removed from the battery string.Data acquisition and analysis of data collected from the modules are available in the DV-B Win application software suite. They provide data viewing, tracking, and generation of comprehensive reports.

  • Sensor Technology

    Power Monitoring and Diagnostic Technology Ltd.

    PMDT is the only manufacturer to utilize all 5 types of online partial discharge sensor technology. Using multiple sensing methods ensures that PD activity is always discovered, located, and characterized. PMDT's handheld PDetector and PDStar units have more capability than the high-end diagnostic equipment of the past. The small handheld, battery powered unit can completely perform the test and analysis without the need of a PC. PDetector, PDStar, and PDiagnostic instruments feature high-resolution phase-resolved analysis of PD signals (PRPD and PRPS) in real time, so you get your test results instantly!

  • Measurement & Test

    ET Power Systems Ltd.

    Electronic test engineers use a variety of precision instruments for R&D, vendor verification, and production testing. ETPS can supply a number of general test instruments that can be used in stand alone mode or automated for high throughput testing. Dedicated battery test systems with automatic charge and discharge modes with data logging are available. The standard 16 and 32 channel systems have range up to 5VDC ensuring their suitability for a wide variety of cells.

  • Analogue (1kV below) Insulation Tester

    2732 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on "low ohms" : 3Ω & 500Ω.● Compact and lightweight.● AC voltmeter with linear scale up to 600 Vac.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● Designed for meet international standards.● Supplied with high quality test leads.● BS 16 edition.

  • Analogue (1kV below) Insulation Tester

    4132 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on "low ohms" : 3Ω & 500Ω.● Compact and lightweight.● AC voltmeter with linear scale up to 600 Vac.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● Designed for meet international standards.● Supplied with high quality test leads.● BS 16 edition.

  • All in one system 32KWH LiFePO4 Lithium Battery with AC Charger and 15KW Inverter for mobile vehicle application

    SPVLI-32KWH-INV15KW - Zhejiang Sandi Electric Co., Ltd

    Our All in one system 32KWH LiFePO4 Lithium Battery with AC Charger and 12-15KW 120/240V Inverter for mobile vehicle application ESS including LiFePO4 Lithium Battery with BMS, off grid pure sine wave inverter, AC/DC charger.All-in-one design, high integration and space saving installation;Using high-performance lithium iron phosphate cells, laser welding, good cell consistency, designed service life of more than 10 years; Charging and discharging are controlled separately, which is convenient and reliable to control charging and discharging. The discharge port will not be disconnected when over-charging, and the charging port will not be disconnected when over-discharging, the system has good stability;Master-slave mode, passive equalization, can manage the equalization resistance, can set the equalization start voltage difference, and monitor the equalization resistance temperature, more intelligent and safe, and reduce the impact of barrel effect on system energy storage;BMS adopts NXP(USA) automotive-grade high-performance chips, with strong anti-interference, good reliability and wide temperature range;CAN2.0 communication interface, has the advantages of strong real-time performance, long transmission distance, strong anti-electromagnetic interference ability;System parameters can be set through the host computer, such as fan start/stop temperature, charger maximum current setting, charge and discharge current correction, SOC correction, with insulation leakage detection function to prevent oil leakage and short circuit of the cell;Integrate Solar charge controller or AC charger optional, BMS communication control, more safe and reliable;Cell temperature management, can be automatically controlled with the air conditioner heater according to the cell condition to make the cell works at the most suitable temperature, and can be linked with the fire protection system as neededModel SPVLI-30KWH-INV12KWIsolation mode Low Frequency TransformerInverter PartBattery Input Rated Voltage (Vdc) 307VDC Voltage range (Vdc) 278-400VAC Output Rated output power 12KW Output waveform Pure Sine Wave Rated Voltage 120/240VAC Phases Split phase + N + PE Rated current (A) 50A(Phase Current) Frequency 60Hz Power Factor (PF) >0.95 Inverter Efficiency >92% Display LCD Overload Ability 150%, 35 secondsAC-DC Charger PartAC Input Voltage range(Vac) 180-240VacDC Output Rated voltage(Vdc) 330Vdc Rated current(A) 20ALithium Battery PartCell/Number 105AH/96PCSRated voltage 307VMax charge current 20AMax discharge current 100ACharge temperature range 0℃ ~ 50℃Discharge temperature range -20℃ ~ 50℃Cell charge end voltage 3.6VCell discharge end voltage 2.7VProtection Function Protection Input reverse polarity, under voltage, over voltage, output over-current, short circuit, overheating etc. Cooling method Fan-cooledDegree of protection IP20(indoor)Mechanical Dimension Depth* Width * Height 645x891x767mm Weight (Kg) 378Kg

  • Battery Cell Formation System

    17000 series - Chroma ATE Inc.

    Chroma 17000 series is specifically designed for the formation of Lithium Ion and Lithium Polymer secondary batteries. The 17000 series is a complete turn-key system, including carrier trays, robust battery probe contacts, high quality charge/discharge modules and intuitive software all under computer control. Patented Battery Voltage Tracking (BVT) DC-DC conversion power modules minimize power consumption in battery charging, and Energy Recycle Modules (ERM) recycle the discharged energy directly back to the DC power system for increased power efficiency. These power saving designs provide a planet friendly solution along with cost savings by reducing energy consumption. The intuitive software provides a flexible selection in the charge/ discharge channel, current rating, and modules under test. These features allow the Series 17000 to be used for final cell development, pilot line production, high volume production and ongoing reliability monitoring/quality control.

  • Regenerative Battery Pack Test System

    17040 - Chroma ATE Inc.

    Conforms to international standards for battery testing: IEC, ISO, UL, and GB/T, etc.Regenerative battery energy discharge (Eff. >90%, PF >0.95, I_THD <5%)Multiple voltage and current ranges for auto ranging function to provide optimum resolutionHigh accuracy current/voltage measurement (0.05%FS/0.02%FS)2ms current slew rate (-90% ~ 90%)Dynamic (current/power) driving profile simulation tests for NEDC, FUDS, HPPCTest channel parallel functionTest data analysis functionData recovery protection (after power failure)Automatic protection for error conditionBattery simulator (option)High power testing equipment- Voltage range : 80~1000V - Current range : 0~750A - Power range : 0~300kWCustomized integration functions- Integrated temperature chamber - BMS data analysis - Multi-channel voltage/temperature recording

  • Lithium Battery Test Chambers

    Dongguan Amade Instruments Technology Co., Ltd

    Lithium battery test chambers are used to simulate various extreme conditions such as crush, impact, penetration, overcharge etc the lithium ion cells and batteries are subjected to during use, transportation, storage and disposal to determine the safety performances, tests including altitude simulation test, thermal test, vibration test, shock test, external short circuit test, impact/crush test, overcharge test, discharge test etc based on UN38.3, IEC62133, UL1642 standards. Applicable to communication products, computer products, consumer electronics, automobile power supplies and so on.

  • UNIVERSAL SYNCHRONOUS BALANCE CHARGER/DISCHARGER

    U113AD - Astro Flight Inc.

    The U113AD charger is a fully integrated AC or DC powered charger capable of charging up to 150W. The built-in AC power supply allows the charger to be powered from a 110V wall socket at home or in the shop. The included DC input power plugs can be connected to a 12V lead-acid/gel cell batteries for charging at the field or track. The U113AD has the ability to charge, discharge and cycle Lithium (LiPo, LiIo, LiFe) packs up to 8 cells, NiCad and NiMH packs up to 26 cells, and Lead Acid batteries up to 36V. This is 12V higher than most battery chargers at this price point and is extremely useful for 36V applications such as E-bikes and scooters!

  • Transformer Ratio Meters

    Handheld Turns Ratio & Winding Resistance Tester TWR-H - Amperis sl

    TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.

  • Programmable DC Electronic Load - (Economical)

    63200E Series - Chroma ATE Inc.

    The 63200E series are high power DC loads that include a choice of three operating voltages, 150V, 600V and 1,200V, with power levels from 2kW to 24kW and up to 2,000A in a single unit. Power levels can increase up to 240kW when multiple units are paralleled.These high power loads are designed for testing a wide range of EV products including DC charging stations, car battery discharge, on board charger power components, and other power electronics components. With its high power capabilities, parallel control and dynamic synchronization functions make this load ideal for automotive batteries, fuel cells and more. The 63200E load's master/slave control application enables units with the samevoltage specification to be used in parallel and synchronized dynamically to meet the power testing requirements. In addition, a 255-set data storage function has been built-in for recall of the stored settings at any time. When used in automated testing, the save and recall functions can save a great deal of time.